Category: Unidrive M
200 V | 400 V | 575 V | 690 V
Unidrive M’s modular drive offering provides a flexible method of building compact, reliable high-power solutions.
Paralleled together, Unidrive M can control asynchronous and permanent magnet motors in systems up to 2.8 MW (4,200 hp).
Minimize downtime for critical operations
Reliability assured
Create flexible systems easily
Flexible and easy system design
Make compact, easily maintainable systems
Reduce spares inventory
Unidrive M’s modular approach gives customers the opportunity to standardize their solutions in order to keep spares holding to a minimum as different systems can be serviced using one common spare. Large volumes of standard product modules are stocked at local distribution hubs in convenient locations around the world meaning that rapid delivery is always available to all customers.
Upgrade Unidrive SP modular systems painlessly
Migration of Unidrive SP modular systems to Unidrive M is fast and easy:
Environmental safety and electrical conformance
Create high performance solutions
Intelligence:
Onboard comms:
Feedback:
Machine safety:
Keypad:
Option slots:
Parameter cloning via:
VOLTAGE RATINGS |
|
100 V (100 V - 120 V ± 10%) |
|
200 V (200 V - 240 V ± 10%) |
✓ |
400 V (380 V - 480 V ± 10%) |
✓ |
575 V (500 V - 575 V ± 10%) |
✓ |
690 V (500 V - 690 V ± 10%) |
✓ |
CONTROL MODE |
|
Open loop vector or V/Hz induction motor control |
✓ |
Open loop Rotor Flux Control for induction motors (RFC-A) |
✓ |
Open loop permanent magnet motor control (RFC-S) |
✓ |
Closed loop Rotor Flux Control for induction motors (RFC-A) |
✓ |
Closed loop permanent magnet motor control (RFC-S) |
✓ |
Active Front End (AFE) power quality convertor |
✓ |
MODULAR DRIVES:
FRAME SIZE |
DIMENSIONS (H X W X D) |
|
---|---|---|
mm |
in |
|
INVERTER& RECTIFIER | ||
9A |
1108 x 310 x 290 | 43.62 x 12.21 x 11.4 |
9E | 9T |
1069 x 310 x 290 | 42.1 x 12.21 x 11.4 |
10E | 10T | 1069 x 310 x 290 | 42.1 x 12.21 x 11.4 |
11E | 11T |
1242 x 310 x 312 | 48.9 x 12.2 x 12.3 |
INVERTER | ||
9D |
773 x 310 x 290 | 30.4 x 12.2 x 11.4 |
10D |
773 x 310 x 290 | 30.4 x 12.2 x 11.4 |
11D |
863 x 310 x 290 | 34 x 12.2 x 12.3 |
RECTIFIER | ||
10A |
6 pulse
355 x 310 x 290
|
6 pulse
13.9 x 12.2 x 11.4
|
11A | 11T |
6 pulse |
6 pulse |
All dimensions include mounting brackets
Keypad
|
Remote Keypad All the features of the CI-Keypad LCD, but remote mountable. This allows flexible mounting on the outside of a panel and meets IP66 (NEMA 4) |
|
KI-Keypad Plain text, multi-language LCD keypad with up to 4 lines of text for in depth parameter and data descriptions, for enhanced user experience |
|
KI-Keypad RTC All the features of the KI-Keypad, but with battery operated realtime clock. This allows accurate time stamping of events, aiding diagnostics |
System Integration Modules - Feedback
|
SI-Encoder Quadrature encoder input interface module |
|
SI-Universal Encoder Encoder input and output interface supporting Quadrature, SinCos, EnDat and SSI encoders |
System Integration Modules - Communications
|
SI-PROFIBUS PROFIBUS interface module |
|
SI-DeviceNet DeviceNet interface module |
|
SI-CANopen CANopen interface module. |
|
SI-Ethernet External Ethernet module that supports EtherNet/IP and Modbus TCP/IP |
|
SI-EtherCAT |
SI-PROFINET RT PROFINET interface module |
System Integration Modules - Applications
|
SI-Applications Second processor module, which allows SyPTPro application programs to be re-compiled for Unidrive M700 |
|
MCi200 Second processor, providing advanced machine control using Machine Control Studio |
|
MCi210 Adds to the MCi200 with a dual port Ethernet interface directly on the processor and additional I/O |
System Integration Modules - Additional I/O
|
SI-I/O Extended I/O interface module to increase the number of I/O points on a drive. Provides additional: 4 x Digital I/O, 3 x Analog inputs (default)/Digital inputs, 1 x Analog output (default)/Digital input, 2 x Relays |
System Integration Modules - Safety
|
SI-Safety An intelligent, programmable module to meet the IEC 61800-5-2/ISO 13849-1 functional safety standard up to SIL3/PLe |
Drive interface units - Back-up
|
Smartcard Smartcard memory device to back-up and copy parameter sets and basic PLC programs |
SD Card Adaptor Allows an SD card to be inserted into the Smartcard slot, for parameter backup cloning and application programs |
Drive interface units - Communications
KI-485 Adaptor
This allows the drive to communicate via RS485. This is commonly used for programming if the drive has no keypad
|
|
|
CT USB Comms Cable The USB Comms cable allows the drive to connect to a PC for use with Unidrive M's PC tools* |
* Also requires an adaptor.
Commissioning and monitoring software
|
Unidrive M Connect - Commissioning tool Based on Control Techniques’ 25 years' experience, Unidrive M Connect is our latest drive configuration tool for commissioning, optimizing and monitoring drive/system performance |
Automation and motion programming software
|
Machine Control Studio - Programming tool Control Techniques' Machine Control Studio provides a flexible and intuitive environment for programming Unidrive M’s new automation and motion control features. |